Air Inlet Valve Actuator Replacement Delphi
                    
Removal Procedure
Notice: In order to avoid actuator damage, DO NOT apply power to the actuator when it is not installed in the HVAC module.
- Remove the air distribution duct. Refer to 
Air Distributor Duct Replacement
 .
 
- Disconnect the electrical connection from the recirculation actuator (1).
 
- Remove the recirculation actuator retaining screws.
 
- Remove the recirculation actuator.
 
Installation Procedure
- Install the recirculation actuator.
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the recirculation actuator retaining screws.
 
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
- Connect the electrical connector to the recirculation actuator (1).
 
- Install the air distribution duct. Refer to 
Air Distributor Duct Replacement
 .
 
                            Air Inlet Valve Actuator Replacement Visteon
                    
Removal Procedure
Notice: In order to avoid actuator damage, DO NOT apply power to the actuator when it is not installed in the HVAC module.
- Remove the HVAC module assembly. Refer to 
HVAC Module Assembly Replacement
 .
 
- Remove the screws from the evaporator core cover (1).
 
- Remove the evaporator core cover (1) from the HVAC module assembly (2).
 
- Remove the screws from the recirculation actuator (1).
 
- Remove the recirculation actuator (1) from the HVAC module assembly (2).
 
Installation Procedure
- Install the recirculation actuator (1) to the HVAC module assembly (2).
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the screws to the recirculation actuator (1).
 
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Install the evaporator core cover (1) to the HVAC module assembly (2).
 
- Install the screws to the evaporator core cover (1).
 
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Install the HVAC module assembly. Refer to 
HVAC Module Assembly Replacement
 .
 
- Reprogram the recirculation actuator. Refer to 
Actuator Recalibration
 .