| Table 1: | Body Control Module | 
| Table 2: | Heating and Air Conditioning | 
| Table 3: | Rear Auxiliary Climate Module | 
| Table 4: | Rear HVAC | 
| Table 5: | Engine | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)  | |||
Left Solar Sensor  | Data  | Counts  | Varies  | 
Right Solar Sensor  | Data  | Counts  | Varies  | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)  | |||
A/C Switch  | Input/Output  | On/Off  | Off  | 
AC Permission  | Input/Output  | Withheld/Granted  | Varies  | 
Air Inlet Door Actual  | Door Positions  | Counts  | Varies  | 
Air Inlet Door Commanded  | Door Positions  | Counts  | Varies  | 
Air Inlet Motor Drive  | Door Positions  | Stop/Increase/Decrease  | Stop  | 
Air Mix Door Left Commanded  | Door Positions  | Counts  | Varies  | 
Air Mix Door Right Commanded  | Door Positions  | Counts  | Varies  | 
Auto Switch  | Input/Output  | On/Off  | Off  | 
Battery Voltage  | Input/Output  | Volts  | 13.5-14.5 V  | 
Blower Motor PWM Speed  | Door Positions  | Percent  | 12-114%  | 
Engine Coolant Temp  | Sensor Data  | °C/°F  | Varies  | 
Fan Down Button  | Input/Output  | On/Off  | Off  | 
Fan Up Button  | Input/Output  | On/Off  | Off  | 
Front Defrost Switch  | Input/Output  | On/Off  | Off  | 
Ign. Since Current DTC  | Input/Output  | Numeric  | 0 Cycles  | 
Inside Air Temp. Sensor  | Sensor Data  | °C/°F  | Varies  | 
Inside Air Temp. Fan  | Sensor Data  | On/Off  | On  | 
Left Mix Door Actual  | Door Positions  | Counts  | Varies  | 
Left Mix Motor Drive  | Door Positions  | Stop/Increase/Decrease  | Stop  | 
Left Temp. Setting  | Input/Output  | °C/°F  | Varies  | 
LH AC Duct Actual  | Sensor Data  | Counts  | Varies  | 
LH AC Duct Desired  | Sensor Data  | Counts  | Varies  | 
LH Heater Duct Actual  | Sensor Data  | Counts  | Varies  | 
LH Heater Duct Desired  | Sensor Data  | Counts  | Varies  | 
Mode Door Actual  | Door Positions  | Counts  | Varies  | 
Mode Dr. Motor Command  | Door Positions  | Counts  | Varies  | 
Mode Motor Drive  | Door Positions  | Stop/Increase/Decrease  | Stop  | 
Mode Select Position  | Door Positions  | Off/Auto/Defrost/Heater/Htr./Def./Bi-Level/Panel  | Varies  | 
Mode Switch  | Input/Output  | On/Off  | Off  | 
Off Switch  | Input/Output  | On/Off  | Off  | 
Outside Air Temp. Filtered  | Input/Output  | °C/°F  | 22-27°C (70-80°F)  | 
Outside Air Temp. Raw  | Input/Output  | °C/°F  | Varies  | 
Pressure Cycle Switch  | Input/Output  | Low Pressure/Normal  | Varies  | 
Recirculate Switch  | Input/Output  | On/Off  | Off  | 
RH AC Duct Actual  | Sensor Data  | Counts  | Varies  | 
RH AC Duct Desired  | Sensor Data  | Counts  | Varies  | 
RH Heater Duct Actual  | Sensor Data  | Counts  | Varies  | 
RH Heater Duct Desired  | Sensor Data  | Counts  | Varies  | 
Right Mix Door Actual  | Door Positions  | Counts  | Varies  | 
Right Mix Motor Drive  | Door Positions  | Stop/Increase/Decrease  | Stop  | 
Right Temp. Setting  | Input/Output  | °C/°F  | Varies  | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)  | |||
Air Temp. Switch Pos.  | Front Aux. Controls  | Numeric  | Varies  | 
Ambient Air Temp. Sensor  | Data  | °C/°F  | Varies  | 
Aux. Temp Dr. Motor Command  | Door Positions  | Counts  | Varies  | 
Aux. Temp Dr. Motor Status  | Door Positions  | Stop/Increase/Decrease  | Stop  | 
Aux. Temp Dr. Position  | Door Positions  | Counts  | Varies  | 
Battery Voltage  | Data  | Volts  | 13.5-14.5 Volts  | 
Blower Switch Pos.  | Front Aux. Controls  | Numeric  | Varies  | 
Engine Coolant Temp.  | Data  | °C/°F  | Varies  | 
Ign. Since Current DTC  | Data  | Cycles  | 0 Cycles  | 
Inside Air Temp. Fan  | Input/Output  | On/Off  | On  | 
Inside Air Temp. Sensor  | Data  | Counts  | Varies  | 
Lower Heater Duct Actual  | Data  | Counts  | Varies  | 
Mode Door Actual  | Door Positions  | Counts  | Varies  | 
Mode Motor Drive  | Door Positions  | Stop/Increase/Decrease  | Stop  | 
Mode Dr. Motor Command  | Door Positions  | Counts  | Varies  | 
Mode Switch Pos.  | Front Aux. Controls  | Numeric  | Varies  | 
Rear HVAC Fan Select Pos.  | Input/Output  | Auto/Off/Low/Med/High  | Auto  | 
Rear HVAC Mode Select Pos.  | Input/Output  | Auto/Floor/Bi-Level/Panel  | Auto  | 
Upper Htr. Duct Actual  | Data  | Counts  | Varies  | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)  | |||
Battery Voltage  | Data  | Volts  | 13.5-14.5 Volts  | 
Ign. Since Current DTC  | Data  | Cycles  | 0 Cycles  | 
Rear HVAC Fan Down Sw.  | Data  | Active/Inactive  | Inactive  | 
Rear HVAC Fan Speed  | Data  | Auto/Off/Low/Med/High  | Auto  | 
Rear HVAC Fan Up Switch  | Data  | Active/Inactive  | Inactive  | 
Rear HVAC Mode Switch  | Data  | Active/Inactive  | Inactive  | 
Rear HVAC Motor Pos.  | Data  | Off/Auto/Lower/Bi-Level/Upper  | Varies  | 
Rear Temp. Select Sw.  | Data  | Up/Down/Inactive  | Inactive  | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)  | |||
A/C Pressure Sensor  | Engine Data 2  | kPa/psi  | 629-845 kPa (85-120 psi)  | 
A/C Pressure Sensor  | Engine Data 2  | Volts  | Varies  | 
A/C Relay Command  | Engine Data 2  | On/Off  | Varies  | 
A/C Request Signal  | Engine Data 2  | Yes/No  | Varies  | 
ECT Sensor  | Engine Data 2  | °C/°F  | 92°C (197°F)  |